Product >> Termination>> 3M Cold Shrink QT-III Termination - Single Conductor 冷縮預撐電纜 終端接頭QT-III 電纜處理頭 - 單蕊電纜
    ![]()  | 
    
     QT-III Silicone Rubber - Single Conductor 
    3M Cold Shrink QT-III terminations offer easy 
    installation and reliable performance when terminating indoor and 
    3M高壓終端處理頭第二代(QT2 淺灰色)內建電應力套管,但是終端處理頭之防水處理須要纏繞防水 
    膠帶,於電纜外半導體剝除處須纏繞 #13半導電膠帶及塗抹矽脂膏以防止產生部分放電,未提供電纜油污清潔劑. 
    預撐含膠式 電纜末端處理頭 (QT III Silicone Rubber)  您可能會需要:  | 
  
Cable Types for Terminating
| 
 
 Tape Shielded Cable 
 Wire Shielded Cable 
 UniShield Cable 
 Wire Over Tape Shielded Cable 
 LC Shielded Cable  | 
    
     
  | 
    
 
 Concentric Neutral (CN) Cable 
Jacketed 
Concentric Neutral (JCN) Cable 
Paper Insulated 
Lead Covered (PILC) Cable Nonshielded (Dry) Cable 
 Nonshielded (Wet or Dry) Cable  | 
  
3M Cold Shrink QT-III Indoor Tubular Termination 終端處理頭QT-III 屋內型
| 
     
 產品型號  | 
    
     
 耐衝擊電壓  | 
    
     電纜絕緣外徑 O.D. Range  | 
    
     導體尺寸線徑 AWG AND kcmil (mm2)  | 
  ||||
| 
     5 kV  | 
    
     8 kV  | 
    
     15 kV  | 
    
     25/ 28 kV  | 
    
     35 kV  | 
  |||
| 
     7620-T-95  | 
    
     95 kV  | 
    
     0.32 – 0.59 (8,1 – 15,0)  | 
    
     8 – 4  | 
    
     8 – 6  | 
    
     —  | 
    
     —  | 
    
     —  | 
  
| 
     7621-T-95  | 
    
     95 kV  | 
    
     0.44 – 0.89 (11,2 – 22,6)  | 
    
     2 – 3/0  | 
    
     4 – 2/0  | 
    
     —  | 
    
     —  | 
    
     —  | 
  
| 
     7622-T-95  | 
    
     95 kV  | 
    
     0.64 – 1.08 (16,3 – 27,4)  | 
    
     4/0 – 400  | 
    
     3/0 – 300  | 
    
     —  | 
    
     —  | 
    
     —  | 
  
| 
     7624-T-95  | 
    
     95 kV  | 
    
     0.83 – 1.53 (21,1 – 38,9)  | 
    
     500 – 750  | 
    
     350 – 700  | 
    
     —  | 
    
     —  | 
    
     —  | 
  
| 
     7625-T-95  | 
    
     95 kV  | 
    
     1.05 – 1.80 (26,7 – 45,7)  | 
    
     700 – 1500  | 
    
     600 – 1250  | 
    
     —  | 
    
     —  | 
    
     —  | 
  
| 
     7622-T-110  | 
    
     110 kV  | 
    
     0.64 – 1.08 (16,3 – 27,4)  | 
    
     4/0 – 400  | 
    
     3/0 – 300  | 
    
     2 – 2/0 (35 – 70)  | 
    
     —  | 
    
     —  | 
  
| 
     7623-T-110  | 
    
     110 kV  | 
    
     0.72 – 1.29 (18,3 – 32,8)  | 
    
     300 – 500  | 
    
     250 – 500  | 
    
     2/0 – 300 (70 – 150)  | 
    
     —  | 
    
     —  | 
  
| 
     7624-T-110  | 
    
     110 kV  | 
    
     0.83 – 1.53 (21,1 – 38,9)  | 
    
     500 – 750  | 
    
     350 – 700  | 
    
     4/0 – 500 (120 – 240)  | 
    
     —  | 
    
     —  | 
  
| 
     7625-T-110  | 
    
     110 kV  | 
    
     1.05 – 1.80 (26,7 – 45,7)  | 
    
     700 – 1500  | 
    
     600 – 1250  | 
    
     500 – 1000 (240 – 500)  | 
    
     —  | 
    
     —  | 
  
| 
     7626-T-110  | 
    
     110 kV  | 
    
     1.53 – 2.32 (38,9 – 58,9)  | 
    
     1750 – 2000  | 
    
     1500 – 2000  | 
    
     1250 – 2000 (625 – 1000)  | 
    
     —  | 
    
     —  | 
  
| 
     7693-T-150  | 
    
     150 kV  | 
    
     0.72 – 1.29 (18,3 – 32,8)  | 
    
     300 – 500  | 
    
     250 – 500  | 
    
     2/0 – 300 (70 – 150)  | 
    
     2 – 4/0 (35 – 120)  | 
    
     2 – 2/0 (35 – 70)  | 
  
| 
     7695-T-150  | 
    
     150 kV  | 
    
     1.05 – 1.80 (26,7 – 45,7)  | 
    
     700 – 1500  | 
    
     600 – 1250  | 
    
     500 – 1000 (240 – 500)  | 
    
     250 – 800 (150 – 400)  | 
    
     3/0 – 600 (95 – 325)  | 
  
| 
     7696-T-150  | 
    
     150 kV  | 
    
     1.53 – 2.32 (38,9 – 58,9)  | 
    
     1750 – 2000  | 
    
     1500 – 2000  | 
    
     1250 – 2000 (625 – 1000)  | 
    
     900 – 1750 (500 – 800)  | 
    
     700 – 1500 (400 – 725)  | 
  
| 
     
  | 
    
     
  | 
    
     Cable Insulation O.D. 絕緣層外徑  | 
    
     導體線徑 Conductor Size Range AWG and kcmil (mm2)  | 
    UPC | 
| 
     Kit Number  | 
    
     BIL  | 
    
     Inch (mm)  | 
    
     5 kV  | 
    
     8.7 kV  | 
    
     15 kV  | 
    
     25/28 kV  | 
    
     ★35 kV  | 
    
     054007-  | 
  
Shielded Cable Kits(Each kit makes three terminations) 適用銅帶/線遮蔽電纜
| 
     7620-T-95  | 
    
     95 kV  | 
    
     0.32-0.59 (8,2-15,0)  | 
    
     8-4(10~25)  | 
    
     8-6(10~26)  | 
    
     —  | 
    
     —  | 
    
     —  | 
    
     41758  | 
  
| 
     7621-T-95  | 
    
     95 kV  | 
    
     0.44-0.89 (11,2-22,7)  | 
    
     2-3/0(35~95)  | 
    
     4-2/0(27~70)  | 
    
     —  | 
    
     —  | 
    
     —  | 
    
     41759  | 
  
| 
     7622-T-110  | 
    
     110 kV  | 
    
     0.64-1,08 (16,3-27,4)  | 
    
     4/0-400 (120~200)  | 
    
     3/0-300 (95~150)  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     41760  | 
  
| 
     7624-T-110  | 
    
     110 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750 (250~380)  | 
    
     350-700(170~350)  | 
    
     4/0-500 (120-240)  | 
    
     —  | 
    
     —  | 
    
     41761  | 
  
| 
     7625-T-110  | 
    
     110 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500 (350~725)  | 
    
     600-1250 (300~625)  | 
    
     500-1000 (240-500)  | 
    
     —  | 
    
     —  | 
    
     41762  | 
  
| 
     7626-T-110  | 
    
     110 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000 (800~1000)  | 
    
     1500-2000 (750~1000)  | 
    
     1250-2000 (500-1000)  | 
    
     —  | 
    
     —  | 
    
     41763  | 
  
| 
     7693-T-150  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500 (150~240)  | 
    
     250-500 (150~240)  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120) 25KV 38mm2  | 
    
     2-2/0 (35-70)  | 
    
     41778  | 
  
| 
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500 (350~725)  | 
    
     600-1250 (300~625)  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400) 25kv 125 /250 m2  | 
    
     3/0-600 (95-325)  | 
    
     41779  | 
  |
| 
     7696-T-150  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000 (800~1000)  | 
    
     1500-2000 (750~1000)  | 
    
     1250-2000 (500-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     41780  | 
  
Concentric and Jacketed Concentric Cable Kits (Each kit makes one termination)
| 
     7642-T-110  | 
    
     110 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     41764  | 
  
| 
     7644-T-110  | 
    
     110 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350-700  | 
    
     4/0-500 (120-240)  | 
    
     —  | 
    
     —  | 
    
     41766  | 
  
| 
     7645-T-110  | 
    
     110 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     —  | 
    
     —  | 
    
     41768  | 
  
| 
     7646-T-110  | 
    
     110 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (500-1000)  | 
    
     —  | 
    
     —  | 
    
     41770  | 
  
| 
     7653-T-150  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)  | 
    
     41772  | 
  
| 
     7655-T-150  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     3/0-600 (95-325)  | 
    
     41774  | 
  
| 
     7656-T-150  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (500-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     41776  | 
  
High Fault Current Cable Kits(Each kit makes one termination)
| 
     7642-T-HSG-110  | 
    
     110 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     41765  | 
  
| 
     7644-T-HSG-110  | 
    
     110 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350-700  | 
    
     4/0-500 (120-240)  | 
    
     —  | 
    
     —  | 
    
     41767  | 
  
| 
     7645-T-HSG-110  | 
    
     110 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     —  | 
    
     —  | 
    
     41769  | 
  
| 
     7646-T-HSG-110  | 
    
     110 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (500-1000)  | 
    
     —  | 
    
     —  | 
    
     41771  | 
  
| 
     7653-T-HSG-150  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-120)  | 
    
     41773  | 
  
| 
     7655-T-HSG-150  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     3/0-600 (95-325)  | 
    
     41775  | 
  
| 
     7656-T-HSG-150  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (500-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     41777  | 
  
★
150kV impulse level meets the impulse requirements for 35.0kV class equipment where indoor terminations are used.3M Cold Shrink QT-III Outdoor Skirted Termination 終端處理頭QT-III 屋外型
| 
     | 
    
     | 
  
| 
     | 
    
| 
     
  | 
    
     
  | 
    
     Cable Insulation O.D.  | 
    
     Conductor Size Range AWG and kcmil (mm2)  | 
    UPC | 
| 
     Kit Number  | 
    
     BIL  | 
    
     Inch (mm)  | 
    
     5 kV  | 
    
     8.7 kV  | 
    
     15 kV  | 
    
     25/28 kV  | 
    
     ★35 kV  | 
    
     054007-  | 
  
Shielded Cable Kits(Each kit makes three terminations) 適用銅帶/線遮蔽電纜
| 
     7620-S-2  | 
    
     95 kV  | 
    
     0.32-0.59 (8,2-15,0)  | 
    
     8-4 (10-25)  | 
    
     8-6 (10-16)  | 
    
     —  | 
    
     —  | 
    
     —  | 
    
     42168  | 
  ||
| 
     7621-S-2  | 
    
     95 kV  | 
    
     0.44-0.89 (11,2-22,7)  | 
    
     2-3/0 (35-95)  | 
    
     4-2/0 (25-70)  | 
    
     —  | 
    
     —  | 
    
     —  | 
    
     42169  | 
  ||
| 
     7622-S-2  | 
    
     110 kV  | 
    
     0.64-1,08 (16,3-27,4)  | 
    
     4/0-400 (120-200)  | 
    
     3/0-300 (95-150)  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     42170  | 
  ||
| 
     7692-S-4  | 
    
     150 kV  | 
    
     0.64-1,08 (16,3-27,4)  | 
    
     4/0-400 (120-200)  | 
    
     3/0-300 (95-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-1/0 (35-50)  | 
    
     —  | 
    
     42211  | 
  ||
| 
     7693-S-4  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500 (150-240)  | 
    
     250-500 (130-240)  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     42212  | 
  ||
| 
     7694-S-4  | 
    
     150 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750 (240-380)  | 
    
     350-700 (170-350)  | 
    
     4/0-500 (120-240)  | 
    
     2/0-250 (70-150)  | 
    
     —  | 
    
     42213  | 
  ||
| 
     7695-S-4  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500 (350-725)  | 
    
     600-1250 (300-625)  | 
    
     500-1000 (240-500)  | 
    
     250-800 (125-400)  | 
    
     —  | 
    
     42214  | 
  ||
| 
     7696-S-4  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000 (800-1000)  | 
    
     1500-2000 (725-1000)  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     —  | 
    
     42215  | 
  ||
| 
     7683-S-8  | 
    
     200 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500 (150-240)  | 
    
     250-500 (125-240)  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)  | 
    
     42465  | 
  ||
| 
     7684-S-8  | 
    
     200 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750 (240-380)  | 
    
     350-700 (170-350)  | 
    
     4/0-500 (120-240)  | 
    
     2/0-250 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     42466  | 
  ||
| 
     7685-S-8  | 
    
     200 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500 (350-725)  | 
    
     600-1250 (300-625)  | 
    
     500-1000 (240-500)  | 
    
     250-800 (125-400)  | 
    
     3/0-600 (95-325)  | 
    
     42467  | 
  ||
| 
     7686-S-8  | 
    
     200 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000 (800-1000)  | 
    
     1500-2000 (725-1000)  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     42468  | 
  ||
Concentric and Jacketed Concentric Cable Kits(Each kit makes one termination)
| 
     7642-S-2  | 
    
     110 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0–300  | 
    
     2–4/0 (35–120)  | 
    
     —  | 
    
     —  | 
    
     42011  | 
  
| 
     7652-S-4  | 
    
     150 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0–300  | 
    
     2–4/0 (35–120)  | 
    
     2-1/0 (35-120)  | 
    
     —  | 
    
     42178  | 
  
| 
     7653-S-4  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250–500  | 
    
     2/0–300 (70–150)  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     42192  | 
  
| 
     7654-S-4  | 
    
     150 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350–700  | 
    
     4/0–500 (120–240)  | 
    
     2/0-250 (70-150)  | 
    
     —  | 
    
     42203  | 
  
| 
     7655-S-4  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600–1250  | 
    
     500–1000 (240–500)  | 
    
     250-800 (150-400)  | 
    
     —  | 
    
     42208  | 
  
| 
     7656-S-4  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500–2000  | 
    
     1250–2000 (625–1000)  | 
    
     900-1750 (500-800)  | 
    
     —  | 
    
     42210  | 
  
| 
     7663-S-8  | 
    
     200 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250–500  | 
    
     2/0–300 (70–150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)  | 
    
     42433  | 
  
| 
     7664-S-8  | 
    
     200 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350–700  | 
    
     4/0–500 (120–240)  | 
    
     2/0-250 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     42447  | 
  
| 
     7665-S-8  | 
    
     200 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600–1250  | 
    
     500–1000 (240–500)  | 
    
     250-800 (150-400)  | 
    
     3/0-600 (95-325)  | 
    
     42461  | 
  
| 
     7666-S-8  | 
    
     200 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500–2000  | 
    
     1250–2000 (625–1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     42463  | 
  
| 
     Kit No.  | 
    
     BIL  | 
    
     Cable Insulation O.D. Range in. (mm)  | 
    
     5 kV  | 
    
     8.7 kV  | 
    
     Conductor Size Range AWG and kcmil (mm2) 15 kV  | 
    
     25/28 kV  | 
    
     35 kV  | 
    
     UPC (054007-)  | 
  
High Fault Current Cable Kits(Each kit makes one termination)
| 
     7652-S-HSG-4  | 
    
     150 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     2-1/0 (35-50)  | 
    
     —  | 
    
     42171  | 
  
| 
     7653-S-HSG-4  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     42185  | 
  
| 
     7654-S-HSG-4  | 
    
     150 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350-700  | 
    
     4/0-500 (120-240)  | 
    
     2/0-250 (70-150)  | 
    
     —  | 
    
     42199  | 
  
| 
     7655-S-HSG-4  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     —  | 
    
     42207  | 
  
| 
     7656-S-HSG-4  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     —  | 
    
     42209  | 
  
| 
     7663-S-HSG-8  | 
    
     200 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)  | 
    
     42440  | 
  
| 
     7664-S-HSG-8  | 
    
     200 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     500-750  | 
    
     350-700  | 
    
     4/0-500 (120-240)  | 
    
     2/0-250 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     42454  | 
  
| 
     7665-S-HSG-8  | 
    
     200 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (125-400)  | 
    
     3/0-600 (95-325)  | 
    
     42462  | 
  
| 
     7666-S-HSG-8  | 
    
     200 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)  | 
    
     42464  | 
  
Inverted Kits for Shielded Cable(Each kit makes three terminations)
Inverted
| 
     7622-S-INV-2  | 
    
     110 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     43016  | 
  |
| 
     7693-S-INV-4  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)*  | 
    
     43017  | 
  |
| 
     7695-S-INV-4  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     3/0-600 (95-325)*  | 
    
     43018  | 
  |
| 
     7696-S-INV-4  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (500-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)*  | 
    
     43019  | 
  |
Inverted Kits for Concentric and Jacketed Concentric Cable(Each kit makes one termination)
| 
     7642-S-INV-2  | 
    
     110 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
    
     04622  | 
  
| 
     7653-S-INV-4  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     2-2/0 (35-70)*  | 
    
     04625  | 
  
| 
     7655-S-INV-4  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     3/0-600 (95-325)*  | 
    
     04623  | 
  
| 
     7656-S-INV-4  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     700-1500 (400-725)*  | 
    
     04624  | 
  
*35kV weather protected applications only
3M Cold Shrink QT-III Silicon Rubber Termination with Top Insulator
| 
     Kit No.  | 
    
     BIL  | 
    
     Cable Insulation O.D. Range in. (mm)  | 
    
    
     Connector & Drop Wire O.D. Range  | 
    
     5 kV  | 
    
     8.7 kV  | 
    
     Conductor Size Range AWG and kcmil (mm2) 15 kV  | 
    
     25/28kV  | 
    
     UPC (054007-)  | 
  
Concentric and Jacketed Concentric Cable Kits with Top Insulator (Each kit makes one termination)
| 
     7642-S-4-TI  | 
    
     
  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     0.97-1.48 (24,6-37,6)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     —  | 
    
     —  | 
  
| 
     7652-S-4-TI  | 
    
     150 kV  | 
    
     0.64-1.08 (16,3-27,4)  | 
    
     0.51-0.82 (12,9-20,8)  | 
    
     4/0-400  | 
    
     3/0-300  | 
    
     2-4/0 (35-120)  | 
    
     2-1/0 (35-50)  | 
    
     43409  | 
  
| 
     7653-S-4-TI  | 
    
     150 kV  | 
    
     0.72-1.29 (18,3-32,8)  | 
    
     0.62-1.0 (15,7-25,4)  | 
    
     300-500  | 
    
     250-500  | 
    
     2/0-300 (70-150)  | 
    
     2-4/0 (35-120)  | 
    
     43410  | 
  
| 
     7654-S-4-TI  | 
    
     150 kV  | 
    
     0.83-1.53 (21,1-38,9)  | 
    
     0.66-1.18 (16,7-30,0)  | 
    
     500-750  | 
    
     350-700  | 
    
     4/0-500 (120-240)  | 
    
     2/0-250 (70-150)  | 
    
     43411  | 
  
| 
     7655-S-4-TI  | 
    
     150 kV  | 
    
     1.05-1.80 (26,7-45,7)  | 
    
     0.69-1.30 (17,5-33,0)  | 
    
     700-1500  | 
    
     600-1250  | 
    
     500-1000 (240-500)  | 
    
     250-800 (150-400)  | 
    
     43412  | 
  
| 
     7656-S-4-TI  | 
    
     150 kV  | 
    
     1.53-2.32 (38,9-58,9)  | 
    
     1.05-1.94 (26,6-49,3)  | 
    
     1750-2000  | 
    
     1500-2000  | 
    
     1250-2000 (625-1000)  | 
    
     900-1750 (500-800)  | 
    
     43413  | 
  
高壓電與處理頭,各式產品比較表:
| 冷縮式 | 熱縮式 | 預鑄式 | |
| 電應力控制方法 | 折射擴散法 | 形狀擴散法 | 折射擴散法 | 
| 材質(耐候性) | 矽橡膠 | EVA | EPDM | 
| 適用範圍 | 一套管可適用多種線徑 庫存管理簡易 | 一套管可適用多種線徑 庫存管理簡易 | 一個電力錐,僅適用一種線徑庫存管理不易 | 
| 施工時間(不含電讚準備工作) | 約6分鐘即可完成 | 約15分鐘可完成 | 約15分鐘可完成 | 
| 施工品質 | 穩定可靠 | 視工作人員熟練程度而定 | 視工作人員熟練程度而定 | 
| 完成長度 | 約350mm(25kV,屋內) | 約580mm(25kV,屋內) | 約530mm(25kV,屋內) | 
| 防水性 | 佳 | 尚可 | 尚可 | 
| 電纜彎折配合度 | 可隨電纜彎折,不影響 其防水性(適形性佳) | 不好 | 不好 | 
| 技術支援及售後服務 | 技術中心在台提供 技術支援,售後服務 | 原廠代理商在台 提供售後服務 | 由貿易商引進 | 
| 交貨 | 國內生產,交貨迅速 | 國內並沒有工廠生產 | 國內並沒有工廠生產 | 