Product >> TE Connectivity ENTRELEC Terminal Block >> Entrelec Terminal Block Screw Clamp
5 mm spacing Terminal Block, 22 to 12 AWG
6 mm spacing Terminal Block, 22 to 10 AWG
8 mm spacing Terminal Block, 22 to 8 AWG
10 mm spacing Terminal Block, 20 to 6 AWG
5 mm spacing Double Level Terminal Block, 22 to 12 AWG
6 mm spacing Double Level Terminal Block, 22 to 10 AWG
MA 2,5/5 - 0 to 4 mm2 (22 to 12 AWG), 30 Amps, 5 mm
![]() |
MA 2,5/5 Spacing 5 mm (.200") Standard 5 mm block |
![]() |
MA 2,5/5.P Spacing 5 mm (.200") Terminal block for ground wir |
| Type | P/N | |||
|---|---|---|---|---|
| Standard blocks | Grey body | MA 2,5/5 | 115 486 03 | |
| Blue body | MA 2,5/5.N | 125 486 05 | ||
| Yellow body | -- | -- | ||
| Orange body | -- | -- | ||
| Green body | -- | -- | ||
| Red body | -- | -- | ||
| Black body | -- | -- | ||
| Terminal blocks for ground wires | Green / yellow body
(with rail contact) |
MA 2,5/5.P | 165 488 27 | |
| Yellow+Green body (without rail contact) |
-- | -- | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG | Solid wire | 0-4 | 22-12 AWG | 22-12 AWG |
| Stranded wire | 0-2.5 | |||
| Rated voltage | V AC / = DC | 750/900 Gr.C | 600 | 600 |
| Rated current | A | 26 | 30 | 25 |
| Rated wire size | mm2 / AWG | 2.5 mm2 | 12 AWG | 12 AWG |
| Wire stripping length | mm / inches | 10 mm / .39" | ||
| Recommended torque | Nm / lb.in | 0.4-0.6 Nm / 3.5-5.3 lb-in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop (all rails) | BAM | th. 9.1 | 103 002 26 | |
| End section | grey | FEM6 | *th. 2.8 | 118 368 16 | |
| blue | FEM6 | *th. 2.8 | 128 368 10 | ||
| yellow | FEM6 | th. 2.8 | 103 062 21 | ||
| orange | FEM6 | *th. 2.8 | 103 126 16 | ||
| green | FEM6 | *th. 2.8 | 103 125 15 | ||
| Circuit separator | grey | SCMA5 | * | 116 728 25 | |
| Separator end section (block) | grey | SCF6 | *th. 3 | 118 707 03 | |
| Separator end section (rail) | grey | SCFM6 | th. 3 | 114 825 05 | |
| Test socket | DIA. 2 mm | AL2 (1) | * | 163 046 24 | |
| DIA. 3 mm | -- | -- | -- | ||
| DIA. 4 mm | -- | -- | -- | ||
| Test device | DCB | *blue | 105 028 21 | ||
| Test plug | DIA. 2 mm | FC2 | *DIA. 2 | 007 865 26 | |
|
Preassembled jumper bar IP20 touchproof |
2 poles | BJM5 (1) | * | 176 273 01 | |
| 3 poles | BJM5 (1) | * | 176 274 02 | ||
| 4 poles | BJM5 (1) | * | 176 275 03 | ||
| 5 poles | BJM5 (1) | * | 176 276 04 | ||
| 10 poles | BJM5 (1) | * | 176 277 05 | ||
| Connector plate | -- | -- | -- | ||
|
Jumper bar not preassembled Post + screw + washer |
BJS5 (1) | *20 poles | 177 652 06 | ||
| EV5 | * | 168 629 16 | |||
|
Comb-type jumper bar Isolating cover |
10 poles | PC5 | * | 113 544 12 | |
| EIP | * | 113 550 24 | |||
| Shielding connector | CBM5 | *th. 0.5 | 178 745 14 | ||
| CBM8 | *th. 0.8 | 178 746 15 | |||
|
Protection label
Screw for protection label |
3 blocks | -- | -- | -- | |
| 4 blocks | -- | -- | -- | ||
| -- | -- | -- | |||
| Markers (see Accessories section) | RC510 Side and Top | ||||
*Not for MA
2,5/5.P block
(1) A circuit separator SC is required with the use
of these accessories.
(2) Use of these accessories requires the user to cut out
the partition.
M 4/6 - 0 to 4 mm2 (22 to 10 AWG), 30 Amps, 6 mm
![]() |
M 4/6...Spacing 6 mm (.238") Standard 6 mm block |
![]() |
M 4/6.P...Spacing 6 mm (.238") Terminal block for ground wire. |
| Type | P/N | |||
|---|---|---|---|---|
| Standard Blocks | Grey body | M 4/6 | 115 116 07 | |
| Blue body | M 4/6.N | 125 116 01 | ||
| Yellow body | M 4/6 | 105 116 16 | ||
| Orange body | M 4/6 | 105 002 20 | ||
| Green body | M 4/6 | 105 001 27 | ||
| Red body | M 4/6 | 105 032 15 | ||
| Black body | M 4/6 | 105 031 14 | ||
| Terminal
blocks for ground wires |
Green / yellow body (with rail contact) |
M 4/6.P | 165 113 16 | |
| Yellow+green body (without rail contact) |
M 4/6.PI | 165 275 00 | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG** | Solid wire | 0-4 | 22-10 AWG | 24-10 AWG |
| Stranded wire | 0-4 | |||
| Rated voltage | V AC / = DC | 750/900 Gr.C | 600 | 600 |
| Rated current | A | 35 | 30 | 25 |
| Rated wire size | mm2 / AWG | 4 mm2 | 10 AWG | 10 AWG |
| Wire stripping length | mm / inches | 9.5 mm/.37" | ||
| Recommended torque | Nm /lb.in | 0.5-0.8 Nm/4.4-7.1 lb-in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop (all rails) | BAM | th. 9.1 | 103 002 26 | |
| End section | grey | FEM6 | * th. 2.8 | 118 368 16 | |
| blue | FEM6 | * th. 2.8 | 128 368 10 | ||
| yellow | FEM6 | th. 2.8 | 103 062 21 | ||
| orange | FEM6 | * th. 2.8 | 103 126 16 | ||
| green | FEM6 | * th. 2.8 | 103 125 15 | ||
| Circuit separator | grey | SCM6 | * | 113 003 10 | |
| Separator end section (block) | grey | SCF6 | * th.3 | 118 707 03 | |
| Separator end section (rail) | grey | SCFM6 | th.3 | 114 825 05 | |
| Test socket | DIA. 2 mm | AL2(1) | * | 163 043 21 | |
| DIA. 3 mm | AL3(1) | * | 163 261 00 | ||
| DIA. 4 mm | -- | -- | -- | ||
| Test device | DCJ | * yellow | 173 059 03 | ||
| Test plug | DIA. 2 mm | FC2 | * | 007 865 26 | |
|
Preassembled jumper bar IP20 touchproof |
2 poles | BJM6(1) | * | 168 516 25 | |
| 3 poles | BJM6(1) | * | 168 517 26 | ||
| 4 poles | BJM6(1) | * | 168 518 07 | ||
| 5 poles | BJM6(1) | * | 168 519 00 | ||
| 10 poles | BJM6(1) | * | 168 973 07 | ||
| Connector plate | EL6 | * | 173 627 21 | ||
|
Jumper bar not preassembled
Post+screw+washer |
BJS6 (1) | * 20 poles | 174 784 20 | ||
| EV6 | * | 168 604 16 | |||
| Comb-type jumper bar | 10 poles | PC6 | * | 113 548 26 | |
| Isolating cover | EIP | * | 113 550 24 | ||
| Shielding connector | CBM5 | * th. 0.5 | 178 745 14 | ||
| CBM8 | * th. 0.8 | 178 746 15 | |||
|
Protection label Screw for protection label |
3 blocks | -- | -- | -- | |
| 4 blocks | EP6 | * | 163 427 17 | ||
| VSP6 | * | 163 433 15 | |||
| See markers section | RC610 Side - RCT610 Top | ||||
* Not for M4/6.P block
(1) A circuit separator SC is required with the use of these accessories.
(2) Use of these accessories requires the user to cut out the partition.
**UL rated for multiple wires - 2 x 16 or 18 AWG, 3 x 20 or 22 AWG.
M 6/8 - 0 to 10 mm2 (22 to 8 AWG), 50 Amps, 8 mm
![]() |
M 6/8Spacing 8 mm (.315") Standard 8 mm block
|
![]() |
M 6/8.P...Spacing 8 mm (.315") Terminal block for ground wire
|
| Type | P/N | |||
|---|---|---|---|---|
| Standard blocks | Grey body | M 6/8 | 115 118 11 | |
| Blue body | M 6/8.N | 125 118 13 | ||
| Yellow body | M 6/8 | 105 118 20 | ||
| Orange body | M 6/8 | 105 004 22 | ||
| Green body | -- | -- | ||
| Red body | -- | -- | ||
| Black body | -- | -- | ||
|
Terminal blocks for ground wires |
Green / yellow body
(with rail contact) |
M 6/8.P | 165 114 17 | |
| Yellow+green body
(without rail contact) |
M 6/8.PI | 165 451 21 | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG** | Solid wire | 0 - 10 | 22-8 AWG | 24-8 AWG |
| Stranded wire | 0 - 6 | |||
| Rated voltage | V AC / = DC | 750/900 Gr.C | 600 | 600 |
| Rated current | A | 46 | 50 | 55 |
| Rated wire size | mm2 / AWG | 6 mm2 | 8 AWG | 8 AWG |
| Wire stripping length | mm / inches | 12 mm / .47" | ||
| Recommended torque | Nm /lb.in | 0.8-1 Nm / 7.1-8.9 lb-in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop (all rails) | BAM | th. 9.1 | 103 002 26 | |
| End section | grey | FEM6 | *th. 2.8 | 118 368 16 | |
| blue | FEM6 | *th. 2.8 | 128 368 10 | ||
| yellow | FEM6 | th. 2.8 | 103 062 21 | ||
| orange | FEM6 | *th. 2.8 | 103 126 16 | ||
| green | FEM6 | *th. 2.8 | 103 125 15 | ||
| Circuit separator | grey | SCM6 | * | 113 003 10 | |
| Separator end section (block) | grey | SCF6 | *th. 3 | 118 707 03 | |
| Separator end section (rail) | grey | SCFM6 | th. 3 | 114 825 05 | |
| Test socket | DIA. 2 mm | AL2 (1) | * | 163 043 21 | |
| DIA. 3 mm | AL3 (1) | * | 163 261 00 | ||
| DIA. 4 mm | AL4 (1) | * | 163 262 01 | ||
| Test device | DCO | *orange | 173 060 00 | ||
| Test plug | DIA. 2 mm | FC2 | *DIA. 2 | 007 865 26 | |
| Preassembled
jumper bar IP20 touchproof |
2 poles | BJM8 (1) | * | 168 520 05 | |
| 3 poles | BJM8 (1) | * | 168 521 22 | ||
| 4 poles | BJM8 (1) | * | 168 522 23 | ||
| 5 poles | BJM8 (1) | * | 168 523 24 | ||
| 10 poles | BJM8 (1) | * | 168 974 00 | ||
| Connector plate | EL6 | * | 173 627 21 | ||
| Jumper bar not
preassembled Post+screw+washer |
BJS8 (1) | *20 poles | 174 789 05 | ||
| EV6 | * | 168 604 16 | |||
| Comb-type jumper bar Isolating cover |
10 poles | PC8 | * | 163 313 24 | |
| Shielding connector | -- | -- | -- | ||
| Protection label
Screw for protection label |
3 blocks | EP6 | * | 163 427 17 | |
| 4 blocks | EP8 | * | 163 428 20 | ||
| VSP6 | * | 163 433 15 | |||
| See markers section | RC810 Side | ||||
* Not for M 6/8.P block
(1) A circuit separator SC is required with the use of these accessories.
(2) Use of these accessories requires the user to cut out the partition.
**UL rated for multiple wires, 2 x 12 to 16 AWG, 3 x 18 to 22 AWG.
M 10/10 - 0 to 16 mm2 (20 to 6 AWG), 65 Amps, 10 mm
![]() |
M 10/10Spacing 10 mm (.394") Standard 10 mm block
|
![]() |
M 10/10.P...Spacing 10 mm (.394") Terminal block for ground wire |
| Type | P/N | |||
|---|---|---|---|---|
| Standard blocks | Grey body | M 10/10 | 115 120 17 | |
| Blue body | M 10/10.N | 125 120 11 | ||
| Yellow body | M 10/10 | 105 120 26 | ||
| Orange body | -- | -- | ||
| Green body | -- | -- | ||
| Red body | -- | -- | ||
| Black body | -- | -- | ||
| Terminal
blocks for ground wires |
Green / yellow body (with rail contact) |
M 10/10.P | 165 115 10 | |
| Yellow+green body (without rail contact) |
M 10/10.PI | 165 452 22 | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG** | Solid wire | 0 - 16 | 20-6 AWG | 18-6 AWG |
| Stranded wire | 0 - 10 | |||
| Rated voltage | V AC / = DC | 750/900 Gr.C | 600 | 600 |
| Rated current | A | 63 | 65 | 70 |
| Rated wire size | mm2 / AWG | 10 mm2 | 6 AWG | 6 AWG |
| Wire stripping length | mm / inches | 12 mm / .47" | ||
| Recommended torque | Nm / lb.in | 1.2-1.4 Nm/10.6-12.3 lb-in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop (all rails) | BAM | th. 9.1 | 103 002 26 | |
| End section | grey | FEM6 | *th. 2.8 | 118 368 16 | |
| blue | FEM6 | *th. 2.8 | 128 368 10 | ||
| yellow | FEM6 | *th. 2.8 | 103 062 21 | ||
| orange | FEM6 | *th. 2.8 | 103 126 16 | ||
| green | FEM6 | *th. 2.8 | 103 125 15 | ||
| Circuit separator | grey | SCM6 | * | 113 003 10 | |
| Separator end section (block) | grey | SCF6 | *th. 3 | 118 707 03 | |
| Separator end section (rail) | grey | SCFM6 | th. 3 | 114 825 05 | |
| Test socket | DIA. 2 mm | AL2 (1) | * | 163 043 21 | |
| DIA. 3 mm | AL3 (1) | * | 163 261 00 | ||
| DIA. 4 mm | AL4 (1) | * | 163 262 01 | ||
| Test device | -- | -- | -- | ||
| Test plug | DIA. 2 mm | FC2 | *DIA. 2 | 007 865 26 | |
|
Preassembled jumper bar IP20 touchproof |
2 poles | BJM10 (1) | * | 173 611 21 | |
| 3 poles | BJM10 (1) | * | 173 612 22 | ||
| 4 poles | BJM10 (1) | * | 173 613 23 | ||
| 5 poles | BJM10 (1) | * | 173 614 24 | ||
| 10 poles | BJM10 (1) | * | 173 615 25 | ||
| Connector plate | BJS10 (1) | 20 poles | 177 654 00 | ||
|
Jumper bar not preassembled Post + screw + washer |
EV6 | * | 168 604 16 | ||
| PC10 | * | 163 315 26 | |||
|
Comb-type jumper bar Isolating cover |
10 poles | -- | -- | -- | |
| -- | -- | -- | |||
| Shielding connector | -- | -- | -- | ||
| -- | -- | -- | |||
|
Protection label Screw for protection label |
3 blocks | EP8 | * | 163 428 20 | |
| 4 blocks | EP10 | * | 163 429 21 | ||
| VSP6 | * | 163 433 15 | |||
| Markers (see Accessories section) | RC65 - RC610 - RC810 | ||||
*Not for M 10/10.P block
(1) A circuit separator SC is required with the use of these accessories.
(2) Use of these accessories requires the user to cut out the partition.
**UL rated for multiple wires, 2 x 12 to 16 AWG, 3 x 18 or 20 AWG.
MA 2,5/5.D2 - 0 to 4 mm2(22 to 12 AWG) 20 Amps - 5 mm spacing
![]() |
For high density applications, allow up to 120 wires per 300 mm (per foot) of panel space. Spacing 5 mm (.200") Standard 5 mm block |
| Type | P/N | |||
|---|---|---|---|---|
| Standard blocks | Grey body | MA 2,5/5.D2 | 115 490 13 | |
| Blue body | MA 2,5/5.D2.N | 125 490 15 | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG | Solid wire | 0 to 4 | 22 to 12 AWG | 20 to12 AWG |
| Stranded wire | 0 to 2.5 | |||
| Rated voltage | V AC / =DC | 750/900 Gr.C | 300 | 300 |
| Rated current | A | 26 | 20 | 25 |
| Rated wire size | mm2 / AWG | 2.5 mm2 | 12 AWG | 12 AWG |
| Wire stripping length | mm /inches | 9 mm / .35" | ||
| Recommended torque | Nm / lb.in | 0.4-0.6 Nm / 3.5-5.3 lb.in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop 35 x 15 | BAEH | th. 12 | 116 934 04 | |
| End stop 35 x 15 x 2.3 | BADH | th. 12 | 116 900 27 | ||
| End section | grey | FEM6D | th. 1 | 118 499 23 | |
| blue | FEM6D | th. 1 | 128 499 25 | ||
| Circuit separator | grey | SCMA5D | th. 1 | 116 720 21 | |
| Separator end section | grey | -- | -- | -- | |
| Test socket | DIA. 2 mm | AL2 (1) | 164 950 00 | ||
| DIA. 3 mm | -- | -- | -- | ||
| DIA. 4 mm | -- | -- | -- | ||
| Test device | DCV | green | 173 058 02 | ||
| Test plug | DIA. 2 mm | FC2 | DIA. 2 | 007 865 26 | |
|
Preassembled jumper bar IP20 touchproof see section accessories |
2 poles | BJM5D | 176 226 22 | ||
| 3 poles | BJM5D | 176 227 23 | |||
| 4 poles | BJM5D | 176 228 04 | |||
| 5 poles | BJM5D | 176 229 05 | |||
| 10 poles | BJM5D | 176 230 02 | |||
| Connector plate | -- | -- | -- | ||
|
Jumper bar not preassembled Post + screw +washer |
BJS5D | 20 poles | 177 651 05 | ||
| EV5D | 176 260 10 | ||||
|
Comb-type jumper bar Isolating cover |
10 poles | PC5 | 113 544 12 | ||
| EIP | 113 550 24 | ||||
| Vertical interconnection | ITV5 | 176 259 13 | |||
| Shielding connector | CBM5D | th. 0.5 | 173 530 24 | ||
| See markers section | RC510 | ||||
M 4/6.D2 - 0 to 4 mm2 (22 to 10 AWG) 20 Amps - 6 mm spacing
![]() |
For high density applications, allow up to 100 wires per 300 mm (per foot) of panel space. Spacing 6 mm (.238") Standard 6 mm block |
| Type | P/N | |||
|---|---|---|---|---|
| Standard blocks | Grey body | M 4/6.D2 | 115 271 22 | |
| Blue body | -- | -- | ||
| Characteristics | DIN-VDE | UL | CSA | |
| Wire size mm2 / AWG | Solid wire | 0 to 4 | 22 to 10 AWG | 18 to 10 AWG |
| Stranded wire | 0 to 4 | |||
| Rated voltage | V AC / =DC | 750/900 Gr.C | 300 | 300 |
| Rated current | A | 26 | 20 | 25 |
| Rated wire size | mm2 / AWG | 4 mm2 | 10 AWG | 10 AWG |
| Wire stripping length | mm /inches | 8.5 mm / .33" | ||
| Recommended torque | Nm / lb.in | 0.5 to 0.8 Nm/4.4 to 7.1 lb.in | ||
| Accessories | Type | P/N | |||
|---|---|---|---|---|---|
|
|
End stop 35 x 15 | BAEH | th. 12 | 116 934 04 | |
| End stop 35 x 15 x 2.3 | BADH | th. 12 | 116 900 27 | ||
| End section | grey | FEM6D | th. 1 | 118 499 23 | |
| blue | FEM6D | th. 1 | 128 499 25 | ||
| Circuit separator | grey | SCM6D | 113 482 05 | ||
| Separator end section | grey | SCF6D | th. 1 | 118 495 17 | |
| Test socket | DIA. 2 mm | AL2(1) | 163 070 00 | ||
| DIA. 3 mm | AL3(1) | 163 261 00 | |||
| DIA. 4 mm | -- | -- | -- | ||
| Test device | DCG | grey | 163 218 05 | ||
| Test plug | DIA. 2 mm | FC2 | DIA. 2 | 007 865 26 | |
|
Preassembled jumper bar IP20 touchproof |
2 poles | BJM61 (1) | 173 515 11 | ||
| 3 poles | BJM61 (1) | 173 516 12 | |||
| 4 poles | BJM61 (1) | 173 517 13 | |||
| 5 poles | BJM61 (1) | 173 519 25 | |||
| 10 poles | BJM61 (1) | 173 520 22 | |||
| Connector plate | EL6 | 173 627 21 | |||
|
Jumper bar not preassembled Post + screw + washer |
BJS61 (1) | 10 poles | 168 485 27 | ||
| EV6D | 168 400 16 | ||||
| Comb-type jumper
bar Isolating cover |
10 poles | PC61 | 163 311 22 | ||
| Vertical interconnection | ITV6 | 168 962 04 | |||
| Shielding connector | CBM5D | th. 0.5 | 173 530 24 | ||
| See markers section | RC610 | ||||
UL rated for multiple wires, 2 x 16 or 18 AWG, 3 x 20 or 22 AWG.
中央商業有限公司 Power Hub Inc.